Get a Quote
ZNCLBS magnetic stirrer

Heating Mantle With Variac Control

For Reference Price: Get Latest PriceGet Latest Price

This magnetic stirrer can be widely used in the fields of microorganisms, laboratories, chemistry, etc. It is resistant to high temperature, wear resistance, chemical corrosion, and strong magnetism.

uses for Variac - All About Circuits

uses for Variac - All About Circuits

Aug 20, 2018 Aug 19, 2018. #3. Best use ever. Use it to control the heating power of an electric fry pan. It's always been a pet peeve of mine that the thermostat on an electric fry pan is sooooo imprecise - and that it tries to control temperature instead of heating power. It is impossible to set it to do a simmer on anything.

Get More
Heaters and Heating Mantles - Fisher Sci

Heaters and Heating Mantles - Fisher Sci

Bibby Scientific Electrothermal Heating Element for EM/EME, Capacity: 250 mL, For Use With: 14314 EM Series Heating Mantles, Voltage: 230 V, Frequency: 50/60 Hz. Pricing and Availability. Electrothermal™ CMUT Series Multi-Volume Controlled Mantle. Accommodates round bottom flasks between 250 to 1000mL capacity.

Get More
Heating mantle controller at Thomas Scientific

Heating mantle controller at Thomas Scientific

Controller is 4; W x 5; D x 3.7 ; H. All units are supplied with a 6ft separable power cord, a grounded, 3-wire receptcle and lighted power switch. Controller for use with CG-14000 and CG-14002 Heating Mantles rated at 30 or 60 Volts. 3-Year…. Related Products: Heating Mantles With …

Get More
Electrical Heating Mantles with Controllers Fisher Scientific

Electrical Heating Mantles with Controllers Fisher Scientific

Controllers provide accurate manual control of heating mantles, tapes and all other resistive loads with an adjustable output range from 5 to 100% of the rated voltage. Controller is 8 W x 6 D x 3.7 H. All units are supplied with a 6ft separable power cord, a grounded, 3-wire receptacle and lighted power switch. 3-Year warranty.OptiChem is a ...

Get More
Heating Mantles Selection Guide: Types Features

Heating Mantles Selection Guide: Types Features

For this reason, heating mantles should never be plugged directly into a wall socket. Instead, a transformer, such as a variac, or some form of electronic relay or switch, should be used between the heating mantle and the wall socket. Configurations. Heating mantles are available in the following configurations: Mantle and controller unit ...

Get More
Heating Mantle with Regulator Control Model: MS-E-102

Heating Mantle with Regulator Control Model: MS-E-102

General Specification: Heating Element Temperature : Up to 450℃ max. Temp. Controller : Analog temperature controller (Built-in K type sensor) Thermal Insulation : Ceramic fiber. Material. Mantle : Powder coated aluminum case. Body : Polypropylene. Indicator Lamps : Green- “Power on”, Yellow- “Heater on”.

Get More
Heating Mantles - Glas-Col

Heating Mantles - Glas-Col

Glas-Col invented the Electric Heating Mantle in 1939 and has continued to be the industry leader for Laboratory and Industrial heating ever since. Our products are known for exceptional performance, reliability and durability. common sizes available. fabric interiors conform and protect glassware. available in both aluminum and fabric ...

Get More
Heating Mantle at Thomas Scientific

Heating Mantle at Thomas Scientific

Glas-Col. Provides precise manual control of heating mantles, tapes, cords and other resistive loads Adjustable output range from 3-100% of rated voltage Mount on lattice work or bench top Model 5915A01 will accommodate non-conductive loads to 1200 watts; model 5915A05 to 2400 watts. Electrical….

Get More
Heating Mantle PCE Instruments

Heating Mantle PCE Instruments

In case of heating mantle it goes about a device which is used in laboratories to heat special media in glass vessels. Due to the various sizes of the glass vessels the exact amounts of liquids can be heated. ... The heating mantle helps to heat or control the temperature of different samples or chemicals in the laboratory. The device has a ...

Get More
Hydration of 1-Hexene - Lab Flow Flashcards Quizlet

Hydration of 1-Hexene - Lab Flow Flashcards Quizlet

In order to heat a round bottom flask in a heating mantle, plug the heating mantle into a Variac or Powermite. Turn the heat up gradually, and do not exceed 50-60% of the maximum output of the device. ... Identify items that can be used to control the boiling when heating liquid in a round bottom flask. Select one or more: A stir bar and stir plate

Get More
Lab Heating Mantles - Grainger Industrial Supply

Lab Heating Mantles - Grainger Industrial Supply

Lab Heating Mantles. Laboratory heating mantles from Grainger can provide uniform heat across the surfaces of flasks and beakers to help meet required temperatures. Choose from spherical and lower hemisphere heating mantles with 850F maximum temperature capacities and molded fiberglass liners that can fit snugly on round-bottom flasks.

Get More
The Glassware Gallery: Heating Sources -

The Glassware Gallery: Heating Sources -

Mar 15, 2017 ALWAYS plug the heating mantle into a grounded variable voltage transformer or percentage timer control (which runs at full power but cycles on and off to control the heat). Such devices are often known by the trademarked name, Variac (below, left) or MiniTrol (below, middle). Start with the lowest power setting -- 20-30% power is usually ...

Get More
Sciencemadness Discussion Board - Heating mantle/variac

Sciencemadness Discussion Board - Heating mantle/variac

Nov 05, 2015 Heating mantle/variac Hello all, first post after months of lurking. I bought glassware,a variable temp heating mantle with stirrer and a variac. ... If the heating mantle has temperature control built in, you don't need the variac. As below, so above. Magpie. lab constructor. Posts: 5939 Registered: 1-11-2003 Location: USA Member Is Offline

Get More
Benchtop Controller for Mantle Heater - Omega Engineering

Benchtop Controller for Mantle Heater - Omega Engineering

Oct 09, 2019 Plug the mantel heater directly into output 2 of the benchtop control. Connect the benchtop via USB to a PC running either Windows 7 or 10. Use the configuration program to program the benchtop controller, including temperature set point, range, and sensor type. Program the benchmark controller to change color between green, amber, and red to ...

Get More
Heating Mantles VWR

Heating Mantles VWR

SP Wilmad-LabGlass Hemispherical Micro Heating Mantles, SP Industries. Catalog Number: (14200-156) Limited time offers. Supplier: SP Industries. Description: These micro heating mantles are made of soft, all glass fabric and support …

Get More
Molecular Sieve Drying - University of Massachusetts Amherst

Molecular Sieve Drying - University of Massachusetts Amherst

The baking is very easily accomplished using a heating mantle driven by a Variac (Variable AC Autotransformer) or some other power control device. Every lab/department seems to have both of these items lurking in back corners. For the 380 Watt Heating Mantle shown, the Variac set to 60 gives the right temperature; measure once with a ...

Get More
An Inexpensive Controller for Heating Mantles - NASA/ADS

An Inexpensive Controller for Heating Mantles - NASA/ADS

The conventional way to control the power to a heating mantle is through the use of a Variac. In a typical undergraduate teaching laboratory there are some 20 heating mantles in use at any given time, requiring some 20 Variacs, at a cost of approximately 180 each (for an inexpensive one). The price of an inexpensive Variac is usually greater than that of an expensive mantle.

Get More
An Inexpensive Controller for Heating Mantles - NASA/ADS

An Inexpensive Controller for Heating Mantles - NASA/ADS

The conventional way to control the power to a heating mantle is through the use of a Variac. In a typical undergraduate teaching laboratory there are some 20 heating mantles in use at any given time, requiring some 20 Variacs, at a cost of approximately 180 each (for an inexpensive one). The price of an inexpensive Variac is usually greater than that of an expensive mantle. …

Get More
Organic laboratory Heat Sources - chem.ucalgary.ca

Organic laboratory Heat Sources - chem.ucalgary.ca

The heating element within the insulated mantle is wired to plug i nto a Variac controller which in turn is plugged into a 115 volt outlet. Never plug the mantle directly into a 115 volt outlet; you might burn out the heating element. In operat ing a heating mantle, the controller should initially be off and reading zero voltage.

Get More
Related News

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.