Get a Quote
ZNCLBS magnetic stirrer

Principle Of Heating Mantle

For Reference Price: Get Latest PriceGet Latest Price

This magnetic stirrer can be widely used in the fields of microorganisms, laboratories, chemistry, etc. It is resistant to high temperature, wear resistance, chemical corrosion, and strong magnetism.

SOP for Maintenance and Calibration of Heating Block

SOP for Maintenance and Calibration of Heating Block

5.12.1 Operate the Heating block as per SOP for operating instruction for the heating block. 5.12.2 Insert five BET tubes in a different location of wells and then add 200 ml SWFI with the help of micropipette. 5.12.3 Now insert a calibrated thermometer into the tubes containing 200 ml WFI. 5.12.4 Set the Heating block at 37C temperature.

Get More
Heating Mantles High Temp Glas-Col - VWR

Heating Mantles High Temp Glas-Col - VWR

Aluminum housed mantle for applications requiring more heat.When handling organic liquid samples, the heating mantles are alternatives to Bunsen burners and hotplates. In contrast to other heating devices, glassware containers may be placed in direct contact with the heating mantle without the risk of glassware shattering. While fabric constructed styles can be molded …

Get More
1.4K: Reflux - Chemistry LibreTexts

1.4K: Reflux - Chemistry LibreTexts

Apr 07, 2022 If using a heating mantle, hold it in place with an adjustable platform (e.g. a wire mesh / ring clamp). Allow a few inches below the mantle so when the reaction is complete, the mantle can be lowered and the flask cooled. If the heating mantle is not a perfect fit for the size of the round bottomed flask, surround the flask with sand to create ...

Get More
1.4G: Heating Mantles - Chemistry LibreTexts

1.4G: Heating Mantles - Chemistry LibreTexts

Apr 07, 2022 The mantle will remain warm even after turning off the Variac, and therefore flasks have to be removed from the mantle in order to cool (Figure 1.52c). Figure 1.52: a+b) Distillation using a heating mantle, c) Cooling of a flask after heating. Safety note: the main hazard with heating mantles is that flammable organic liquids spilled on the ...

Get More
ORGANIC LABORATORY TECHNIQUES 10

ORGANIC LABORATORY TECHNIQUES 10

being used to heat the round bottom flask. In your equipment set up (or any of the others), the heating mantle and heating controller will be replaced by an engineered (shaped) aluminium block sitting on the top of a stirrer hot plate. This is a more modern version of a heating mantle with some distinct benefits. Distillation of a Pure Liquid

Get More
Colony Counter Heating Mantle Kjeldahl Digestion Unit

Colony Counter Heating Mantle Kjeldahl Digestion Unit

Construction of mantle using glass yarn. Capability of handling temperatures up to 350 C. Comes supported with energy regulator. Technical Specifications: Made available in sizes of 250ml, 500ml, 1000ml, 2000ml, 3000ml, 10000ml. Work on 220 v ac. Applications: Used for heating flasks containing sample. Used in research labs.

Get More
Electric Heating Mantles VWR

Electric Heating Mantles VWR

Designed to Operate Below Red Heat at Maximum Input Voltage.When handling organic liquid samples, the heating mantles are alternatives to Bunsen burners and hotplates. In contrast to other heating devices, glassware containers may be placed in direct contact with the heating mantle without the risk of glassware shattering. While fabric constructed styles can be molded …

Get More
Heating Mantles Brochure - Electrothermal - PDF Catalogs

Heating Mantles Brochure - Electrothermal - PDF Catalogs

Focus on Heating Mantles Electrothermal has over 70 year’s heritage in the design and manufacture of Heating Mantles and is known throughout the world for producing high quality, robust and safe equipment. The range of Electromantles is diverse, offering a heating solution for most applications, including Electromantles for heating and stirring, multi-position, V-shaped …

Get More
Heating Mantles - Glas-Col

Heating Mantles - Glas-Col

Glas-Col invented the Electric Heating Mantle in 1939 and has continued to be the industry leader for Laboratory and Industrial heating ever since. Our products are known for exceptional performance, reliability and durability. common sizes available. fabric interiors conform and protect glassware. available in both aluminum and fabric ...

Get More
Electrothermal Heating Mantles

Electrothermal Heating Mantles

Heating Mantle Spill-Proof 50-1000ml 230V Electrothermal -Thermo Scientific EMX1000/SCE Heating Mantle V-Shaped 10-50ml 230V. List Price: $431.80. Clarkson Price: $388.62. You Save: $43.18 (10 %) Clarkson EMV0050/CE Heating Mantle V-Shaped 10-50ml 230V

Get More
Heating Mantles - Facilities Management

Heating Mantles - Facilities Management

Heating Mantle Types. Shown below are three examples of heating mantles. The one on the left has a shell that supports the flask, the middle one has a hemispherical outer aluminum shell, and the one on the right has a flexible all-fiberglass design. Most chemists prefer the latter two types because these are easiest to use in combination with a ...

Get More
Heating Mantle PCE Instruments

Heating Mantle PCE Instruments

Heating Mantle. In case of heating mantle it goes about a device which is used in laboratories to heat special media in glass vessels. Due to the various sizes of the glass vessels the exact amounts of liquids can be heated. The scope of volumes of heating mantle at PCE ranges from 100 ml up to 10

Get More
Laboratory - Heating Mantles - Page 1 - Safety Emporium

Laboratory - Heating Mantles - Page 1 - Safety Emporium

Heating mantles are the most common method for heating reaction vessels in the laboratory. For more about the practical aspects of these devices, see the Heating Sources Page of our Glassware Gallery.. All heating mantles and tapes must be operated through a power control.These are not designed to be plugged directly into an electrical outlet.Chemical …

Get More
Heating Mantle Safety Tips Lab Manager

Heating Mantle Safety Tips Lab Manager

Heating mantles should not be used for vacuum distillation of heat sensitive or unstable materials. It’s difficult to regulate precise temperature control. 5. Be aware that some older equipment might have asbestos insulation rather than fiberglass. This insulation should be disposed of using the proper channels and replaced with fiberglass.

Get More
Heating mantles VWR

Heating mantles VWR

Heating mantles. Heaters Heating Mantles. Max. 450 C, with temperature regulation. Range of economical heating mantles with earthed element in case of flask breakage. Fire resistant casing with metal base; ... without giving effect to otherwise applicable principles of conflicts of law. The parties shall submit to the exclusive jurisdiction ...

Get More
Heating Mantles VWR

Heating Mantles VWR

In contrast to other heating devices, glassware containers may be placed in direct contact with the heating mantle without the risk of glassware shattering. While fabric constructed styles can be molded to accommodate a wide variety of flask shapes and sizes, the rigid heating mantles are less susceptible to spill or tearing damage. ...

Get More
FAQ of Electric Heating Mantle - Lab Instruments - Lanphan

FAQ of Electric Heating Mantle - Lab Instruments - Lanphan

Mar 03, 2017 FAQ of Electric Heating Mantle 2017-03-03 11:01:00 Nina Original 2776 Summary: Lanphan technical department summed up the frequently asked questions on uses of heating mantle.Please see below. Lanphan electric heating mantle is the most commonly used laboratory equipment to heat and mix liquid or solid-liquid mixture. We have sold many electric …

Get More
Lab Heating Mantle Magnetic Stirrer

Lab Heating Mantle Magnetic Stirrer

The electric heating mantle is made of non-alkali glass fiber as the insulating material, the Cr20Ni80 alloy wire spring is installed in it, and the aluminum silicate wool is insulated by the vacuum-shaped hemispherical insulation body. The outer shell is injection molded at one time, and the upper cover adopts the electrostatic spray molding process.

Get More
Heating Mantle For Flask at Thomas Scientific

Heating Mantle For Flask at Thomas Scientific

These heating mantles are designed for use with round bottom flasks. Features include polyurethane coated aluminum exteriors and a high quality knitted mantle with glass fiber underlay for uniform distribution of heat. Maximum operating temperature is 400C. Mantles can be used in a wide range….

Get More
Stirring Heating Mantles Fisher Scientific

Stirring Heating Mantles Fisher Scientific

These stirring/heating mantles combine the functionality of a heating mantle with a magnetic stirrer providing even heating and mixing. Element temperatures can reach up to 825F (450C) yet the exterior remains cool to the touch. For maximum safety, the flask does not come in direct contact with the heating element.

Get More
Related News

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.