Get a Quote
DRE1002 2002 5002 rotary evaporator

How Rotary Evaporator Valve

For Reference Price: Get Latest PriceGet Latest Price

D-RE-1010 D-RE-1020 D-RE-1050 rotary evaporator are the laboratory equipment sold by our company, with 10L 20L 50L capacity optional, and Power supply includes 220V50HZ and 110V 60HZ.

Rotary Evaporator - MRC- Lab

Rotary Evaporator - MRC- Lab

A motor unit that rotates the evaporation flask or vial containing the user's sample. 2. A vapor duct that is the axis for sample rotation, and is a vacuum-tight conduit for the vapor being drawn off of the sample. 3. A vacuum system, to substantially reduce the …

Get More
Rotary Evaporator Replacement Glassware

Rotary Evaporator Replacement Glassware

Ace Glass rotary evaporator replacement glass, all manufactured in the USA to exacting specifications and standards. ... Lower distribution head with shut-off valve 40657 3955-08 Cold trap inner body 00672 3937-04 PTFE Lid 27479 3937-05 …

Get More
Selecting a Suitable Vacuum Pump for Your Rotary Evaporator

Selecting a Suitable Vacuum Pump for Your Rotary Evaporator

Apr 04, 2019 Ideally, a pump used in a rotovap setup should be oilless and chemical-resistant to make sure it lasts as long as possible. The most commonly used pumps for this purpose are diaphragm (or membrane displacement) pumps. A variety of pumps (from left to right): an ME1 Diaphragm Pump, a VP Series Vacuum Pump, and a MVP 10 basic Vacuum pump.

Get More
5.6A: Overview of Rotary Evaporation - Chemistry LibreTexts

5.6A: Overview of Rotary Evaporation - Chemistry LibreTexts

Apr 07, 2022 A rotary evaporator is essentially a reduced pressure distillation: a solution in a round bottomed flask is placed in the water bath of the apparatus (Figure 5.66a), and rotated while the system is partially evacuated (by a water aspirator or vacuum pump). The reduced pressure in the apparatus causes the solvent to boil at a lower temperature ...

Get More
How to Clean Your Rotary Evaporator Blog

How to Clean Your Rotary Evaporator Blog

Dec 16, 2019 The proper way to clean your rotary evaporator is to take it apart and wash each piece separately. Removable and washable parts include the evaporation flask, condenser, collection flask, and vapor tube. Many manufacturers will provide advice about cleaning a specific rotary evaporator’s components, but these are the basic steps:

Get More
Rotary Evaporators - Heidolph Instruments

Rotary Evaporators - Heidolph Instruments

Developed with users. In close cooperation with users, we developed the Hei-VAP series of rotary evaporators with an emphasis on the essentials: well thought-out details with a focus on features and functions to facilitate everyday laboratory work. Watch the Heidolph stories. Versatile combinations with glassware and extensive accessories offer ...

Get More
Rotary Evaporation in the Kitchen - Cooking Issues

Rotary Evaporation in the Kitchen - Cooking Issues

Fill water bath (usually 2/3 full) with warm to hot water, set the temperature and turn it on. Put the thermometer from the rotovap unit into the water bath. Clean the vapor duct area and install the vacuum seal. Install a DRY evaporation flask. Close off …

Get More
Heidolph 20L Rotary Evaporator VC5000 Chiller - Highest Performing Evap

Heidolph 20L Rotary Evaporator VC5000 Chiller - Highest Performing Evap

Heidolph’s Most Powerful 20L Rotary Evaporator Hei-VAP Industrial For facilities that can utilize 230V / 3ph power, take advantage of Heidolph’s most efficient package for industrial evaporation. The key difference is in the V5000 chiller bringing 200 additional watts of cooling capacity. ... Valve Vacuum Control – Less babysitting, more ...

Get More
EV400H Rotary Evaporator LabTech

EV400H Rotary Evaporator LabTech

LabTech EV400H Rotary Evaporator with manual lift. 115V/60Hz. 1 Year Warranty. ... The unit includes vertical manual lift and has the option for online sample adding through a PTFE valve, granting high efficiency and easy operation. The color digital display and adjustable control knob allows for rotation speed from 20-260rpm.

Get More
Rotary Evaporator Fact Sheet - UMass Amherst

Rotary Evaporator Fact Sheet - UMass Amherst

Rotary Evaporator Fact Sheet . What are Rotary Evaporators? A rotary evaporator (also called as “rotavap” or “rotovap”) is a device used in labs for the efficient and gentle removal of solvents from samples by evaporation. The picture on the right shows what a typical rotary evaporator includes. What are Potential Hazards?

Get More
Key Principles of Rotary Evaporation

Key Principles of Rotary Evaporation

Sep 30, 2021 Rotary Evaporation Working Principles. Rotary evaporation works on the principle that reducing the pressure on the solvent results in the analytes within have a lower evaporation point than at atmospheric pressure. Rotary evaporation is used in both preparative and analytical organic chemistry and can assist users in fractionating liquid-phase ...

Get More
Standard Operating Procedure - Rotary Evaporator

Standard Operating Procedure - Rotary Evaporator

The Rotary Evaporator is a tool which utilizes vacuum, heat, and spinning motion to cause one component to evaporate while leaving the first component behind. Due to the vacuum, ... Make sure the release valve at the top of the condenser is turned to the closed position. 9. Turn on the vacuum. The gauge on the vacuum pump should read 27 in Hg ...

Get More
How to use a rotary evaporator? -

How to use a rotary evaporator? -

Usually a small rotary evaporator consists of four components, they are: 1. Heating the bath. 2. Rotary transmission. 3. Condenser. 4. Solvent collection bottle. RE-201D 301 501 rotary evaporator. How to use the rotary evaporator: 1. Vacuum extraction: According to the process requirements, the higher the vacuum degree, the faster the ...

Get More
Related News

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.