Get a Quote
DRE1002 2002 5002 rotary evaporator

Rotary Evaporator Standard Operating Procedure

For Reference Price: Get Latest PriceGet Latest Price

D-RE-1010 D-RE-1020 D-RE-1050 rotary evaporator are the laboratory equipment sold by our company, with 10L 20L 50L capacity optional, and Power supply includes 220V50HZ and 110V 60HZ.

Rotary Evaporation - Chemistry LibreTexts

Rotary Evaporation - Chemistry LibreTexts

Aug 15, 2021 Rotary Evaporation. Rotary evaporation is the process of reducing the volume of a solvent by distributing it as a thin film across the interior of a vessel at elevated temperature and reduced pressure. This promotes the rapid removal …

Get More
Rotary Evaporators Fisher Scientific

Rotary Evaporators Fisher Scientific

Bump Trap, 250mL, Rotary Evaporator, Modified, 24/40 Top Outer, 14/20 Lower Inner. Similar to CG-1320, but with the addition of two 4mm drain holes at the base of the inner tube to allow solvent to drain back into the evaporation flask. Traps have a 24/40 top outer joint and the listed size of lower inner joint.

Get More
Rotary Evaporator Instruction - Summit Research

Rotary Evaporator Instruction - Summit Research

Dec 14, 2016 Operating steps: Turn on rotovap, set bath temperature from 35-45c. Turn on chiller and set temperature to 0-5c. Turn on vacuum pump and set your controller to right above the cusp of the evaporation rate (generally 100mbar). Allow both coil and bath to reach temperature while vacuum is set and equalized in system to set point.

Get More
How to Clean Your Rotary Evaporator Blog

How to Clean Your Rotary Evaporator Blog

Dec 16, 2019 Connect one socket to the rotovap (where the evaporation flask would usually go). You can secure it in place or hold it with one hand. Note, the flask should not be set to spin during this process. Use your thumb to close the second socket of the two-neck flask. Set the vacuum pump to around 250 mbar and switch it on.

Get More
Rotary Evaporation - an overview ScienceDirect Topics

Rotary Evaporation - an overview ScienceDirect Topics

In a typical procedure, a thin film formed from 25 mg of DOPC in 20 mL CH 2 Cl 2 in a 50-mL evaporation flask is rehydrated with an aqueous solution of 1 M CaCl 2 (5 mL). Rehydration and agitation are performed by gentle spinning of the evaporation flask in the water bath (40 C) of the rotary evaporator, without vacuum.

Get More
Rotary Evaporators - Heidolph Instruments

Rotary Evaporators - Heidolph Instruments

In close cooperation with users, we developed the Hei-VAP series of rotary evaporators with an emphasis on the essentials: well thought-out details with a focus on features and functions to facilitate everyday laboratory work. Versatile combinations with glassware and extensive accessories offer the right configuration for every application.

Get More
SOP on Operation and Calibration of Melting Point Apparatus

SOP on Operation and Calibration of Melting Point Apparatus

Insert the capillary tube in the melting point apparatus when the temperature is about 5 C below the lower limit of the expected melting range and continue heating until melting is complete. Follow the above steps given in the procedure part. Note the melting point of the reference substance. Record the same in the calibration record.

Get More
What Recommended Pressure and Temperature of Rotary Evaporator (Plant ...

What Recommended Pressure and Temperature of Rotary Evaporator (Plant ...

It really helps. Hi Rukman. 100 mbar and 40C seems a little aggressive. Following the rule of 20, if you are setting your bath to 40C, you should set your vacuum such that the boiling point ...

Get More
Melting Point Apparatus - SOP - Pharma Beginners

Melting Point Apparatus - SOP - Pharma Beginners

Jul 20, 2020 Insert the capillary tube in the melting point apparatus when the temperature is about 5 C below the lower limit of the expected melting range and continue heating until melting is complete. Follow the above steps given in the procedure part. Note the melting point of the reference substance. Record the same in the calibration record.

Get More
Standard Operating Procedure: Rotovaps - Chemistry

Standard Operating Procedure: Rotovaps - Chemistry

Jun 06, 2016 pump as per the lab’s accepted procedure for belt drive pumps). Empty the collection reservoir into the solvent waste bottle located in the rotovap hood, remove your sample from the system and if you bumped into the bump trap remove it from the hood and subject it to the typical cleaning method employed by the lab.

Get More
Lesker #3 Evaporator Standard Operating Procedure

Lesker #3 Evaporator Standard Operating Procedure

LESKER #3 EVAPORATOR STANDARD OPERATING PROCEDURE Issue: Rev K Page 3 5.4.2 Scheduling on iLabs allows cancellation within 24 hours of your scheduled time. Please email staff if cancellation within 24 hours. 5.4.3 We discourage last second cancellations. 5.4.4 We discourage scheduled equipment no-shows. 5.5 Scheduling Overnight runs.

Get More
 The Largest Selection of Rotary Evaporators!

The Largest Selection of Rotary Evaporators!

Let us help you find the perfect rotary evaporator for your lab! Call or email our team! We’re happy to answer any questions you might have. +1 603-652-1395 [email protected]

Get More
PVD75_E-beam_Thermal_SOP - University of Pennsylvania

PVD75_E-beam_Thermal_SOP - University of Pennsylvania

May 01, 2017 Lesker PVD75 E-beam/Thermal Evaporator Standard Operating Procedure. Updated on10/1/2021. Note: Make sure that the main chamber is pumped down after use. In stand-by, HV power supply for e-beam behind the right door is OFF. The materials (pellets) provided for PVD-04 (E-beam/thermal)) are: Ti; Ni ; Cr ; Fe ; Pb; NiCr

Get More
Standard Operating Procedure Templates SOP Checklists

Standard Operating Procedure Templates SOP Checklists

May 04, 2022 The Purpose of a Standard Operating Procedure Template. Using a well-designed standard operating procedure template, or standard operating procedure form, makes it easier for managers and employees to put the best practices for a specific job to be done or an established business process into a clearly-communicated, systematically-written …

Get More
Standard Operating Procedure (SOP) - UCI

Standard Operating Procedure (SOP) - UCI

o The centrifugation standard operating procedure (SOP) must be completed and signed by every member of the laboratory. o Safety data sheets (SDS) for each material should be reviewed prior to use. o Manufacturer operating manual should be reviewed prior to use. Training o Training must be completed prior to working in the laboratory.

Get More
Standard Operating Procedures: A Writing Guide

Standard Operating Procedures: A Writing Guide

Oct 05, 2012 Return to the first cow and thoroughly wipe with a clean towel. Attach unit to first cow and adjust. Repeat steps 5 and 6 with the second and third cows in the side. Begin at step 1 with the fourth cow on the side and repeat procedure with …

Get More
Standard Operating Procedure Centrifuge Safety

Standard Operating Procedure Centrifuge Safety

Standard Operating Procedure . Centrifuge Safety . SOP Number: SOP-CS-02 Category: Lab Equipment Supersedes: SOP-CS-01.1 Original Date: December 1, 2017 Revised: May 1, 2019 Pages 1 of 9 Issued by: Director, Health Sciences Research . 1.0 POLICY. This procedure describes the standard operation for using the ambient and refrigerated

Get More
STANDARD OPERATING PROCEDURE - OMMSWCC

STANDARD OPERATING PROCEDURE - OMMSWCC

STANDARD OPERATING PROCEDURE FORM NO.HSE/CORP/4 ACTIVITY SITE SMC DEPARTMENT Mining SOP NO. IMFA/SOP/SMC/MINING/01 REVISION 00 EFF DATE: 19.6.14 NO. OF PAGES Page 9 shank of the bit. Place the centralizer over the bit. Bring the DHD-Rod-Rotary assembly to the bit and give forward rotation. Raise the rotary system and

Get More
standard operating procedure (SOP)

standard operating procedure (SOP)

Standard operating procedures provide the policies, processes and standards needed for the organization to succeed. They can benefit a business by reducing errors, increasing efficiencies and profitability, creating a safe work environment and producing guidelines for how to resolve issues and overcome obstacles.

Get More
STANDARD OPERATING PROCEDURES - CLU-IN

STANDARD OPERATING PROCEDURES - CLU-IN

STANDARD OPERATING PROCEDURES SOP: 2048 PAGE: 1 of 16 REV: 0.0 DATE: 07/12/01 MONITOR WELL INSTALLATION CONTENTS 1.0 SCOPE AND APPLICATION* ... Rotary drilling can utilize mud rotary or air rotary methods. These are standard (i.e., typically applicable) operating procedures which may be varied or changed as required, depending …

Get More
Safety Best Practices Manual - NBAA

Safety Best Practices Manual - NBAA

Standard Operating Procedures – Rotary Wing . HELICOPTER FLIGHT OPERATIONS (GENERAL) All aircraft operations will be conducted in accordance with all applicable FARs, local and national laws, manufacturers’ aircraft manuals and limitations, and this Manual. Aircraft will be operated in an airworthy condition at all times.

Get More
General Operating Rules - Helicopter - NBAA

General Operating Rules - Helicopter - NBAA

Standard Operating Procedures – Rotary Wing. HELICOPTER FLIGHT OPERATIONS (GENERAL) All aircraft operations will be conducted in accordance with all applicable FARs, local and national laws, manufacturers’ aircraft manuals and limitations, and this Manual. Aircraft will be operated in an airworthy condition at all times.

Get More
Rotary Evaporator - MRC- Lab

Rotary Evaporator - MRC- Lab

The main components of a rotary evaporator are: 1. A motor unit that rotates the evaporation flask or vial containing the user's sample. 2. A vapor duct that is the axis for sample rotation, and is a vacuum-tight conduit for the vapor being drawn off of the sample. 3. A vacuum system, to substantially reduce the pressure within the evaporator ...

Get More
Plant Extraction Using Rotary Evaporator - WKIE

Plant Extraction Using Rotary Evaporator - WKIE

The rotary evaporator is the most ideal when it comes to plant extract because it handles large volumes of the mixtures within a short period. This is common especially in mixtures that involve high boiling points. Therefore, the industries that use evaporation as their main extraction process can greatly benefit from this apparatus.

Get More
Asphalt Extraction and Recovery Procedures

Asphalt Extraction and Recovery Procedures

the Rotary Evaporator” – Solution from extraction is distilled by partially immersing the rotating distillation flask of the rotary evaporator in a heated oil bath while the solution is subjected to a partial vacuum and a flow of nitrogen or carbon dioxide (CO 2) gas – The recovered asphalt can be subjected to testing as required

Get More
1 L Rotary Vacuum Evaporator Instruction Manual

1 L Rotary Vacuum Evaporator Instruction Manual

This rotary evaporator is intended for concentration, purification, and fractional distillation of sample solution. This unit is not explosion proof. Do not ... Operating Temp. 5 to 35C Power Consumption 0.35A, 35VA Power Source AC115V, 60Hz Overall Dimensions (mm) 670W x 320D x 530 (790)H 495W x 320D x 920

Get More
Rotary Welding Machine Safe Operating Procedure

Rotary Welding Machine Safe Operating Procedure

This Rotary Welding Machine Safe Operating Procedure (SOP) provides a way for your business to outline step-by-step safe processes when operating a Rotary Welding Machine. Rotary Welding Machine SOP: Provides instructions on the use of the equipment both prior to and during operation. Ensures workers recognise and manage associated hazards and ...

Get More
Is there an alternative method to evaporate solvents

Is there an alternative method to evaporate solvents

You can simulate a rotary evaporator by monting a system compraised of an erlenmeyer over a hot plate magnetic stirrer or a heated ballon, conected to a inclined condenser. The exit of the ...

Get More
Related News

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.